Monday, July 8, 2013

Certification for gloves

Q:  We recently purchased gloves are that are rated to 300 degrees.  They are not certified by a 3rd party.  Does OSHA require gloves to be approved by ANSI?

A:  OSHA requires eye/face, head, and foot protection to meet certain ANSI standards, but not hand protection.  The certification from the manufacturer stating that the gloves are rated to 300 degrees will be what you need.  We recommend that you request the manufacture includes the type of test they performed to determine this rating on the document they provide to you.

Wednesday, July 3, 2013

Recordkeeping

Q: Do I need to keep the OSHA 300A – Summary up to date throughout the year?


A: No, there is no need to fill out the 300A – Summary until January of the following year.

Monday, July 1, 2013

Leading Edge Work

Question:  When installing plywood decking on a suspended concrete slab that is 13 feet high; is fall protection required?
Answer: Yes fall protection is required unless you can prove that fall protection is infeasible or creates a greater hazard than the fall protection systems.  Listed below is the OSHA standard that explains this.

·         1926.501(b)(2)(i) Each employee who is constructing a leading edge 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, or personal fall arrest systems. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.

Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.

We recommend using temporary anchorage points!  These are simple to use and can be installed into concrete or wood.  The use of these anchorage points with either a retractable lifeline with a personal fall arrest harness or a horizontal life line and personal fall arrest harness will ensure you’re in compliance with OSHA!

Thursday, June 20, 2013

Electrical Cord Repair

Q: If the prong is damaged on an extension cord, is it permissible to replace the prong with an approved one, provided the repair is done by a qualified electrician?

A: Yes, OSHA states “Extension cords used in construction may be repaired, so long as the repair returns the cord to the "approved" state required by 1926.403(a)”

Wednesday, June 19, 2013

Eyewash Distances

Q: We don’t handle any corrosive chemicals and only have an eyewash station as an emergency precaution when grinding and other tool use. What is the required distance?


A: OSHA only requires the eyewash station to be immediately adjacent when working with corrosive chemicals. In any other case it is recommended to have the eyewash station as close as possible.


Monday, June 17, 2013

Recordkeeping

Q:  When counting days away from work or light duty, do I count work days or calendar days?

A: You want to count all calendar days that the employee is off, up to 180.

Find recordkeeping tools at our website!

Wednesday, June 5, 2013

Recordkeeping

Q: If we are working 2 weeks on and then 2 weeks off, do we need to record the two weeks off for an injured employee?

A: Yes, the case needs to be recorded for each of the days that he is away from work including the 2 off weeks even though the rest of the company is also not working those days. 

Tuesday, June 4, 2013

E-stops Testing

Q: Are you required to test e-stops, if so what frequency?

A: There is no direct regulation, however it is a good company practice. It would be recommended for testing to be conducted weekly, monthly, or at most quarterly. 

Tuesday, May 21, 2013

Flammable Liquid Inside Storage

Q: How many drums of our resin, which is a class III flammable substance, are we allowed to store inside?

A: The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed 120 gallons in containers or 660 gallons in a single portable tanks. The direct regulation can be found here, 1910.106(e)(2)(ii)(b). 

Wednesday, May 1, 2013

Eye Wash Station

Q: Can a portable eye wash station have the solution off to the side to preserve shelf life?

A: It is recommended that in any portable eye wash station that must be filled manually with solution to have it filled with the solution. This is so that if an employee does have something in the eyes they don’t have to first fill the station before using it.